Box Type |
N/A With 4 in. Deep Backbox - 240 V AC |
Operating Temperature |
N/A -40 to 122 ºC-40 to 250 ºF |
AC Voltage - Heater |
N/A 240 V |
Heater Frequency |
N/A 50 Hz60 Hz |
Flammability Rating |
N/A UL94 V-2 |
Wall Thickness - Backbox |
N/A 0.20 in5.1 mm |
Wall Thickness - Cover |
N/A 0.12 in3.1 mm |
National Electrical Manufacturers Association (NEMA) Rating |
N/A 3R |
| Polycarbonate Enclosure Warranty1 | N/A 1 y |
Silicone Laminate Heater Warranty |
N/A 5 y |
Silicone Laminate Heater Voltage |
N/A 240 V |
Silicone Laminate Heater Frequency |
N/A 50/60 Hz |
Note for Silicone Laminate Heater |
N/A UL Recognized Component |
Silicone Laminate Heater Power |
N/A 100 W |
Life at -10 to -70 Degree Celcius (ºC) (14 to 158 Degree Fahrenheit (ºF)) Temperature |
N/A 5 y |
Fan Voltage - VDC (±10 %) |
N/A 24 V |
Fan Power Rating |
N/A 90 mA |
Fan Life |
N/A 5 y |
Warning for Fan Usage |
N/A The polarity of the circulating fan is important as it only rotates in one direction with red lead being positive. |
Note for Fan Specification |
N/A UL Recognized Component |
Overall Height |
N/A 6.25 in158 mm |
Overall Width |
N/A 4.125 in104 mm |
Overall Depth |
N/A 1.25 in31 mm |
How It Works |
N/A Stopper II® Heated Enclosure consists of a clear, super tough polycarbonate shield, frame and heater. The Stopper II® is mounted on a NEMA 3R enclosure with a Heater which allows an addressable manual pull station to be installed inside or outside in cold temperatures. |
| Warranty2 | N/A 3 y |
Testing |
N/A
It has been tested and approved or listed by:
|
General Information |
N/A
|
Design |
N/A
|
Construction |
N/A
|
Installation |
N/A
|
Electronics |
N/A
|
Options |
N/A
|
Warning |
N/A The enclosure is used to protect UL Listed 38 and 2017 manual initiating outdoor listed devices at temperatures down to -70 ºF (-57 ºC). It is the installer's responsibility to comply with NEC 70 Articles 725 and 760, NFPA 72, and other applicable fire and electrical codes. Conduit or raceway paths need to be sealed as near to the enclosure as possible. Installer should have maintained supervision over the low temperature thermostat. The low temperature monitoring thermostat makes the circuit at +32 ºF (0 ºC) and clears the circuit at +50 ºF (+10 ºC). This listing requires that the fire alarm supervisory control module be only of the latching type. On the appliance mounting plate is a label where you should record the installation date. Also includes serial number and installation date on the instruction sheet for quick reference. |