Model Type |
N/A STI-1200 flush mount and gasket, Gaskets (Indoor/Outdoor Rated) |
Note for Model Type |
N/A
Add NR for no label on horn housing Add CR for custom label on horn housing |
Operating Temperature |
N/A -40 to 121 ºC-40 to 250 ºF |
Power Source |
N/A 9 Volts (V) DC Alkaline Battery included on Standard Stopper II® |
Flush Width |
N/A 7.2 in183 mm |
Flush Height |
N/A 10.2 in259 mm |
Flush Depth |
N/A 3.3 in84 mm |
Surface Width |
N/A 7.2 in183 mm |
Surface Height |
N/A 10.2 in259 mm |
Surface Depth |
N/A 5.5 in140 mm |
| Warranty1 | N/A 3 y |
Testing |
N/A
It has been tested and approved or listed by:
|
How It Works |
N/A Stopper II® consists of a clear, tamperproof, tough polycarbonate shield and frame, but the line includes models with the option of a piezo horn, spacer, Form “C” dry relay contact and gaskets. The cover accommodates most manual pull stations. When the Stopper II® with horn is lifted to gain access to the protected alarm, a piercing self-contained 95 or 105 dB warning horn (at one foot) sounds. Immediate attention is drawn to the area and a prankster will either run or be caught. The cover is connected to the frame by a cable. When the cover is lifted, it drops off of the frame and a horn will sound (models with horn) until the cover is snapped back onto the frame or for the life of the battery. |
General Information |
N/A
|
Design |
N/A
|
Installation |
N/A
|
Electronics |
N/A
|
Options |
N/A
|
Accessories |
N/A
STI-3100 - 2 in. conduit spacer with 1/2 in. conduit entry (no gaskets included) STI-3104 - 2 in. conduit spacer with 3/4 in. conduit entry (includes one 3/4 in. conduit entry gasket) STI-1102 - Replacement horn for cover with alarm STI-1280 - Backplate for Stopper II® and Weather Stopper® series |
Important Notice |
N/A Stopper II® "FIRE" models are intended to be used in areas where the incidence of false fire alarms from manual pull stations is high or has proven to be a serious problem. Any disadvantage of this device is more than balanced when one considers the consequences of false fire alarms, especially if fire service personnel and equipment are responding to a false fire alarm when they are needed for a real fire somewhere else. Add to this the disruption to the facility when false alarms occur. If you have, or may have, a problem with false fire alarms or physical/weather damage to your fire alarm activation devices, the Stopper II® could prove invaluable. |
Warning |
N/A For RC models: UL Listing does not permit relay contacts to connect to the fire alarm or a life safety function. The power supply for horns, according to UL Listing, cannot be connected to a UL Listed fire alarm system. For electrical specifications see install book. RC models contain one set of Form "C" dry contacts. Contacts rated 30 V AC/V DC 1 amp. |