| Items |
/Asset/STI-1200A-HTR.jpg STI-1200A-HTR STI-1200A-HTR Stopper II® Heated Enclosure Type Pull Station Protective Cover |
/ImgCustom/30/placeholder_notavailable.gif STI-1200A-HTR240 STI-1200A-HTR240 Stopper II® Heated Enclosure Type Pull Station Protective Cover |
||
| Description | N/A This protective cover has been helping stop false fire alarms around the world for more than 35 years, without restricting legitimate alarms. This Stopper II® enclosure with heater allows addressable dual monitor modules to be installed inside or outside in temperatures below UL Listing limits or in other NEMA 3R environments. UL/cUL Listing requires outdoor rated stations. The cover offers excellent protection against physical damage (both accidental and intentional), as well as other environments inside and outside. Also ideal for inside of walk-in freezers. | |||
| Box Type | N/A With 4 in. Deep Backbox - 110 V AC | N/A With 4 in. Deep Backbox - 240 V AC | ||
| Flammability Rating | N/A UL94 V-2 | |||
| Wall Thickness - Backbox | N/A 0.20 in5.1 mm | |||
| Wall Thickness - Cover | N/A 0.12 in3.1 mm | |||
| National Electrical Manufacturers Association (NEMA) Rating | N/A 3R | |||
| Polycarbonate Enclosure Warranty1 | N/A 1 y | |||
| Silicone Laminate Heater Warranty | N/A 5 y | |||
| Silicone Laminate Heater Voltage | N/A 110 V | N/A 240 V | ||
| Silicone Laminate Heater Frequency | N/A 50/60 Hz | |||
| Note for Silicone Laminate Heater | N/A UL Recognized Component | |||
| Silicone Laminate Heater Power | N/A 100 W | |||
| Life at -10 to -70 Degree Celcius (ºC) (14 to 158 Degree Fahrenheit (ºF)) Temperature | N/A 5 y | |||
| Duty Cycle at -40 Degree Fahrenheit (ºF) (-40 Degree Celcius (ºC)) Temperature | N/A 16 % | N/A | ||
| Duty Cycle at -70 Degree Fahrenheit (ºF) (-57 Degree Celcius (ºC)) Temperature | N/A 38 % | N/A | ||
| Duty Cycle at -99 Degree Fahrenheit (ºF) (-73 Degree Celcius (ºC)) Temperature | N/A 100 % | N/A | ||
| Fan Voltage - VDC (±10 %) | N/A 24 V | |||
| Fan Power Rating | N/A 90 mA | |||
| Fan Life | N/A 5 y | |||
| Warning for Fan Usage | N/A The polarity of the circulating fan is important as it only rotates in one direction with red lead being positive. | |||
| Note for Fan Specification | N/A UL Recognized Component | |||
| Operating Temperature | N/A -40 to 121 ºC-40 to 250 ºF | N/A -40 to 122 ºC-40 to 250 ºF | ||
| Overall Height | N/A 6.25 in158 mm | |||
| Overall Width | N/A 4.125 in104 mm | |||
| Overall Depth | N/A 1.25 in31 mm | |||
| AC Voltage - Heater | N/A 110 V | N/A 240 V | ||
| Heater Frequency | N/A 50 Hz60 Hz | |||
| How It Works | N/A Stopper II® Heated Enclosure consists of a clear, super tough polycarbonate shield, frame and heater. The Stopper II® is mounted on a NEMA 3R enclosure with a Heater which allows an addressable manual pull station to be installed inside or outside in cold temperatures. | |||
| Warranty2 | N/A 3 y | |||
| General Information |
N/A
|
|||
| Design |
N/A
|
|||
| Construction |
N/A
|
|||
| Installation |
N/A
|
|||
| Electronics |
N/A
|
|||
| Options |
N/A
|
|||
| Accessories | N/A STI-HK3 - Replacement heater | |||
| Testing |
N/A
It has been tested and approved or listed by:
|
|||
| Warning | N/A The enclosure is used to protect UL Listed 38 and 2017 manual initiating outdoor listed devices at temperatures down to -70 ºF (-57 ºC). It is the installer's responsibility to comply with NEC 70 Articles 725 and 760, NFPA 72, and other applicable fire and electrical codes. Conduit or raceway paths need to be sealed as near to the enclosure as possible. Installer should have maintained supervision over the low temperature thermostat. The low temperature monitoring thermostat makes the circuit at +32 ºF (0 ºC) and clears the circuit at +50 ºF (+10 ºC). This listing requires that the fire alarm supervisory control module be only of the latching type. On the appliance mounting plate is a label where you should record the installation date. Also includes serial number and installation date on the instruction sheet for quick reference. | |||
|
||||